Heat pumps that require additional service.
Trane fan motor not running.
Common solutions 3 related videos 9 common solutions for.
Relay boards are often misdiagnosed.
It happened about 3 months ago as well but i took the top off turned it upside down and was able.
It could be a bad fuse or you might have flipped a breaker.
Before replacing the board make sure you check more commonly defective parts particularly the fan motor capacitor and the fan motor itself.
This is usually because an old filter has not been replaced.
Sometimes excessive dust can build up and cause the motor to burn out.
If you experience a blower motor failure you will need professional assistance in replacing it.
No cold air comes out the vents.
If no fan turning and no humming n.
Trane air conditioners provide central cooling that can turn a hot and muggy day into a cool breeze.
Why is the fan on my heat pump not running.
The contacts inside the relay go bad.
If your air conditioner seems to be running constantly your thermostat could be set too high.
We can help you find your model number right away.
Your local trane comfort specialist can help.
If not there may be a problem with wiring the fan motor or compressor run capacitor.
This is much easier and less expensive to repair than a motor going bad.
A weak faulty or shorted capacitor can prevent the motor from running.
Outside fan doesn t run.
They usually stick open never sending the signal to the motor.
Your heat pump may also have old or worn out wiring that needs to be repaired or tightened by a trane comfort specialist.
Just cool air blows out the vents.
Contact an air conditioner troubleshooting pro.
Sometimes it will stop after about 2 minutes but starting yesterday it will not stop the noise.
Trane condenser fan motor does not run.
Reset your thermostat then adjust the temperature to a comfortable level.
This is probably the most common cause.
The relay board provides voltage to many components of the air conditioner including the fan motor.
To find just the right part enter your model number.
Try replacing the fuse or flipping the circuit breaker to the closed position.
The blower motor is not functioning.
Trane condenser fan motor does not run.
Trane xe 1000 fan motor problem solved the fan on the outside trane xe1000 unit is making a terrible squealing noise when running otherwise everything working fine cools heats house like always.
If your unit s fan is not working efficiently or at all however your unit s overall performance can diminish.
If you are unable to diagnosis and fix the problem with your heat pump or if you have additional questions contact your local trane comfort specialist.